Proline Promass E 200
Coriolis flowmeter
The genuine loop-powered flowmeter for minimized cost of ownership
The robust Promass E has a long standing reputation as a cost-efficient solution accurately measuring liquids and gases in a wide range of standard applications in the chemical industry. With genuine loop-powered technology, Proline E 200 enables cost-effective and seamless integration into existing infrastructures. The flowmeter offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology ensures process safety at all times.
This product is not available in this market.
-
Benefits
-
Cost-effective – multi-purpose device; an alternative to conventional volumetric flowmeters
-
Fewer process measuring points – multivariable measurement (flow, density, temperature)
-
Space-saving installation – no in/outlet run needs
-
Convenient device...
-
-
Field of application
Measuring principle operates independently of physical fluid properties such as viscosity or density
Accurate measurement of liquids and gases for a wide range of standard applications.
Device properties
Compact dual-tube sensor
Medium temperature up...
Documents / Manuals / Software
-
Proline Promass E 200
Technical Information
The genuine loop‐powered flowmeter for minimized cost of ownership
Technical Information (TI) -
Proline Promass E 200
PROFIBUS PA
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass E 200
HART
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass E 200
FOUNDATION Fieldbus
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass 200
FOUNDATION Fieldbus
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 200
HART
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 200
PROFIBUS PA
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass E
Brief Operating Instructions
Coriolis sensor
Short Instruction (KA)10/17English -
Proline 200
FOUNDATION Fieldbus
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 200
PROFIBUS PA
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 200
HART
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Replacing the display module
Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50Mounting Instruction (EA) -
Replacing the transmitter
Installation Instructions
Promass 200/TB2, Prosonic Flow B 200, Promag 200
Mounting Instruction (EA) -
Replacing the main electronics module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200
Mounting Instruction (EA) -
Bus plug FF
Installation Instructions
Promag 53, 55, Promag 200, Promass 83, Promass 200, Prowirl 72, 73,
Prowirl 200, Prosonic Flow 92, 93Mounting Instruction (EA) -
Activating application packages
Installation Instructions
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Mounting Instruction (EA) -
Replacing the I/O-Module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200
Mounting Instruction (EA) -
Proline Promass 200
Class I, Division1; Zone 0 for IS
(Ex i Intrinsically safe version)
Safety Instructions
Safety instructions for explosion-hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 200
ATEX: II2G, II1/2G, II2D
IECEx: Zone 1, Zone 0/1, Zone 21
Ex i Version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 200
ATEX: II2G, II1/2G, II2D
IECEx: Zone 1, Zone 0/1, Zone 21
Ex d Version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 200
INMETRO:
Ex d[ia] IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 200
NEPSI:
Zone 2
Ex nA and Ex ic version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 200
INMETRO:
Ex nA IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 200
ATEX: II3G, II1/3G
IECEx: Zone 2, Zone 0/2
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 200
NEPSI:
Zone 1, Zone 0/1, Zone 21
Ex i version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 200
NEPSI:
Zone 1, Zone 0/1, Zone 21
Ex d version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 200
Class I, Division 1; Zone 1 for XP
(Ex d Flameproofed version)
Safety Instructions
Safety instructions for explosion-hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 200
INMETRO:
Ex ia IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 200
PROFIBUS PA
Heartbeat Verification application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 200
Functional Safety Manual
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Heating jacket
For Promass E Coriolis flowmeters
Special Documentation
Heating jacket
For Promass E Coriolis flowmetersSpecial Documentation (SD) -
Proline Promass 200
FOUNDATION Fieldbus
Heartbeat Verification application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 200
HART
Heartbeat Verification application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
GSD Single, GSD_EH_PA_FL_Promass200_0x155F_0x02_0x01_PALIB, 17.08.2015 (Flow, Promass 200)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, AMS_HART_FL_Promass200_0x0054_0x05_0x01, 03.08.2015 (Flow, Promass 200)
HART,
AMS Version: 12.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Promass200_0x1054_0x01_0x02, 14.03.2018 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
AMS Version: 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass200_0x0054_0x05_0x01, 03.08.2015 (Flow, Promass 200)
HART,
PDM Version: 6.1, 8.2 SP 1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promass200_0x0054_0x05_0x01, 21.08.2019 (Flow, Promass 200, 0x0054)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Promass200_0x1054_0x01_0x02, 20.08.2019 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass200_0x0054_0x05_0x01, 21.08.2019 (Flow, Promass 200, 0x0054)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass200_0x155F_0x02_0x01, 17.08.2015 (Flow, Promass 200)
PROFIBUS PA,
PDM Version: 6.1, 8.2 SP 1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Promass200_0x1054_0x01_0x02, 14.03.2018 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 6Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Promass200_0x1054_0x01_0x02, 14.03.2018 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Promass200_0x1054_0x01_0x02, 22.08.2019 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
AMS Version: 12.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_FF_FL_Promass200_0x1054_0x01_0x01, 22.01.2015 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass200_0x0054_0x05_0x01, 03.08.2015 (Flow, Promass 200)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promass200_8x2B_8x2C_PA_FW1_01_zz_Dev_Rev_2, 06.07.2019 (Flow, Promass 200, 0x155F)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.7.0.236Language neutral -
DTM Single, Promass200_8x2B_8x2C_HART_FW1_04_zz_Dev_Rev_5, 13.07.2019 (Flow, Promass 200, 0x0054)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.0.1133Language neutral -
DTM Single, Promass_200_8x2B_8x2C_FF_FW_1_00_zz_Dev_Rev_1, 13.07.2019 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.3.0.150Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Library, PRM_FF_Package_Flow_1_05_00, 22.07.2015 (Flow)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.12Faceplate1.05.00Language neutral -
Faceplate Single, PRM_FF_FL_Promass200_0x1054_0x01_0x01, 22.01.2015 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass200_0x0054_0x05_0x01, 03.08.2015 (Flow, Promass 200)
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Note Single, Release_Notes_Promass200_FF_0x1054_0x01, 23.08.2018 (Flow, Promass 200, 0x1054)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyNote1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 25.10.2019 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 25.10.2019 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 25.10.2019 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Dosimass, Dosimass OEM, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F
Product Code: 8RE-, 8PE-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 8CE-, 8BE-, 84F-, 83F-, 83E-, 80F-, 80E-, 40E-
Declaration Number: HE_01000_02.18
Manufacturer Specification: Food hygieneManufacturer DeclarationGerman , English -
Promass E, Promass F
Product Code: 8E2B-, 8E2C-, 8F2B-
Declaration Number: EC_00060_03.15EU DeclarationGerman , English , fr -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Declaration Number: EC_00238_04.16EU DeclarationGerman , English , fr -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Declaration Number: EC_00237_05.16EU DeclarationGerman , English , fr -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Declaration Number: EC_00236_04.16EU DeclarationGerman , English , fr -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80
Product Code: 8I5B-, 8O1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q1B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X1B-, 8X3B-, 8X5B-, O8X5B-, 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8H1B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8A5B-, 8A3B-, 8A1B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC № RU D-CH.MU62.B.02411MiscellaneousRussian -
Promass X, Promass F, Promass E, Promass 83, Promass P, Promass S, Promass I, Promass O, Promass H, Promass A, Promass 84, Promass 80, Promass 40
Product Code: 8E1B-, 83F-, 83E-, 83H-, 83I-, 83P-, 83M-, 83S-, 83A-, 8F2B-, 8F1B-, 8I1B-, 8S1B-, 83O-, 83X-, 8A1B-, 80F-, 80E-, 80H-, 8E2B-, 80I-, 84F-, 80P-, 80S-, 8O1B-, 80A-, 8P5B-, 8I5B-, 8H5B-, 8S5B-, 8F5B-, 8F3B-, 8E3B-, 8E5B-, 8S3B-, 8I3B-, 8O3B-, 8P3B-, 8H3B-, 8X3B-, 84A-, 8A5B-, 8A3B-, 40E-, 8X5B-, 8S1C-, 8E2C-, 84X-, 8A5C-, 8A3C-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Promass E, Promass F
Product Code: 8E2B-, 8E2C-, 8F2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex ic IIC T6...T1 Gc, Ex ic [ia Ga] IIC T6...T1 Gc, Ex nA II T6...T1 Gc, Ex nA [ia Ga] IIC T6...T1 GcExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: Japan
Approval Agency: CML
Protection: Ex d [ia]Explosion ProtectionJapanese -
Promass F, Promass E, Promass A
Product Code: 8E2C-, 8F2B-, 8E2B-, 8A2B-
Region/Country: Russia
Protection: Ex tb [ia Da] IIIC Txxx°C Db, Ex nA [ia Ga] IIC T6...T1 Gc, Ex d [ia Ga] IIC T6...T1 Ga/Gb, Ex d [ia Ga] IIB T6...T1 Ga/Gb, Ex tb IIIC Txxx°C Db, Ex nA IIC T6...T1 Gc, Ex ic [ia] IIC T6...T1 Ga/Gc, Ex ic [ia] IIB T6...T1 Ga/Gc, Ex ic IIC T6...T1 Gc, Ex ic IIB T6...T1 Gc, [Ex ia] IIC T6...T1 Gb, [Ex ia] IIC T6...T1 Ga/Gb, [Ex ia] IIB T6...T1 Ga/GbExplosion ProtectionRussian -
Promass E, Promass F, Promass A
Product Code: 8E2B-, 8F2B-, O8E2B-, O8F2B-, 8A2B-, 8E2C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D/T6...T1, II,III/1/E,F,G/
Protection: DIP, NIExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 2 D, II 2 G, II 1/2 G, II 2(1) D
Protection: Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass E, Promass F, Promass A
Product Code: 8E2B-, 8F2B-, O8E2B-, O8F2B-, 8A2B-, 8E2C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1
Protection: DIP, ISExplosion ProtectionEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8E2C-, 8F2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 0,1, zone 20,21
Protection: Ex ia IIC T6...T1 Ga/Gb, Ex tD A20/A21 IP6X Txxx°C, Ex iaD 20/21 Txxx°C, Ex d [ia Ga] IIC T6...T1 Ga/GbExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 2 D, II 2 G, II 1/2 G, II 2(1) D
Protection: Ex d [ia], Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex ia, Ex d [ia Ga]Explosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ic, Ex ic [ia Ga], Ex ic [ia], Ex nA, Ex nA [ia Ga]Explosion ProtectionEnglish -
Prowirl R, Prowirl O, Prowirl F, Prowirl D, Prowirl C, Prosonic Flow B, Promass F, Promass E, Promass A, Promag P, Promag H, Promag E
Product Code: O9B2B-, O5P2B-, O5H2B-, 9B2B-, 8F2B-, 8E2C-, 8E2B-, 8A2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 5P2B-, 5H2B-, 5E2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: China
Approval Agency: NEPSI
Category: zone 0,1, zone 20,21
Protection: Ex iaD 20/21 Txxx°C, Ex ia, Ex tD A20/A21 IP6X, Ex d [ia Ga]Explosion ProtectionEnglish -
Promass E, Promass F
Product Code: 8E2B-, 8E2C-, 8F2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex ia IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 GbExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass E, Promass F, Promass A
Product Code: 8E2B-, 8F2B-, O8E2B-, O8F2B-, 8A2B-, 8E2C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1, II,III/1/E,F,G/
Protection: DIP, XP/ISExplosion ProtectionEnglish -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Region/Country: South Africa
Approval Agency: MTEx
Category: zone 1, zone 21, zone 0,1
Protection: Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEnglish -
Promass A, Promass E, Promass F
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-
Region/Country: South Africa
Approval Agency: MTEx
Category: zone 2
Protection: Ex ic, Ex ic [ia Ga], Ex ic [ia], Ex nA, Ex nA [ia Ga], Ex ecExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, O8E2B-, O8F2B-, 8E2C-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 3 G, II 1/3 G
Protection: Ex ic [ia Ga], Ex ic [ia], Ex nAExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex ic, Ex nAExplosion ProtectionEnglish -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 1
Protection: Ex iaExplosion ProtectionPortuguese -
Promass F, Promass E, Promass A
Product Code: 8F2B-, 8E2B-, 8A2B-, 8E2C-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex nAExplosion ProtectionPortuguese -
Promass E, Promass F
Product Code: 8E2B-, 8E2C-, 8F2B-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
Promass E
Product Code: 8E1B-, 8E1C-, 8E2B-, 8E2C-, 8E3B-, 8E5B-, O8E1B-, O8E1C-, O8E3B-, O8E5B-
Region/Country: Europe
Approval Agency: TNOHygienic EquipmentEnglish -
Promass F, Promass E, Promass O, Promass A, Promass X, Promass Q, Promass I, Promass P, Promass S, Promass H, Promass G, Promass 84, Promass 83, Promass 80, Promass 40
Product Code: 8Q5B-, 8F5B-, 8O5B-, 8E5B-, 8X5B-, 8I5B-, 8S5B-, 8P5B-, 8H5B-, 8Q3B-, 8A5B-, 8F3B-, 8O3B-, 8E3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8H1B-, 8O1B-, 8S1B-, 8G1B-, 8S1C-, 8F2B-, 8E2B-, 83F-, 83E-, 8E1C-, 83A-, 83I-, 83S-, 83H-, 83P-, 8E2C-, 80F-, 83O-, 83X-, 80E-, 80A-, 80I-, 80P-, 80S-, 40E-, 80H-, 84X-, 84O-, 84F-, 84A-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6721MetrologyRussian
Accessories / Spare parts
-
-
Nr 34 Order code 71108602
I/O module Flow, 2-wr. 2x4-20mA,HART, Ex
Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: FTM50/FTM51/FTM52. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 34 Order code 71164940
I/O module, 2-wire, PA/FF, PFS, Ex, V2
Non-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS=switch output. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass 200, Prowirl 200, Promag 200.
-
-
-
Order code 71128617
Overvoltage protection (OVP10),1-Channel
4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71128619
Overvoltage protection (OVP20),2-Channel
4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71197334
Transmitter electronics FHX50
Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.
-
Order code
Remote display FHX50 please order with separate order structure.
-
Order code 71296840
Plug M12, VA
To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.
-
-
-
Nr 30 Order code XPD0001-
-
-
-
Order code 71206552
-
Order code 71206554
-
-
-
Nr 34 Order code XPD0015-
-
-
-
Order code 71206555
-
-
-
Nr 34 Order code XPD0016-
I/O module, 2-wire, 4-20mA,HART, PFS, Ex
Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.
-
-
-
Order code 71206556
-
-
-
Nr 37 Order code 71110280
Terminal set 2-wire, I/O module
Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 40 Order code XPD0024-
Display module, SD02, push buttons
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.
-
Nr 40 Order code XPD0025-
Display module, SD03, Touch Control
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.
-
-
-
Nr 20 Order code 71110299
Cover GT20 Alu, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 20 Order code 71110297
Cover GT20 Alu, sight glass, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110301
Cover GT20 Alu, Terminal Ex, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71110302
Cover GT20 Alu, Terminal Ex d, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71185517
Cover GT20 Alu, Terminal, OVP, HNBR
Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 71115505
Kit 10 ext. M20x1,5/G 1/2" (plug brass)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 71115509
Kit 10 ext. M20x1,5/NPT1/2"(plug brass)
-
Nr 15 Order code 50098037
Kit Cable gland Profibus PA
-
Nr 15 Order code 50094984
Kit Cable gland Found. Fieldbus
-
-
-
Nr 65 Order code 71110303
Sealing set GT18/GT19/GT20, EPDM, HNBR
Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 19 Order code 71115175
Housing filter Brass/Ni GT19/20, 1 set
Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 17 Order code 71115176
Set housing securing clamps
Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Order code 71162242
Weather prot. cover GT18/GT19/GT20, 316L
Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/ FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 8X2CXX-
-
Order code XPRFID-
-
Order code DK8003-
-
-
Predecessor