Proline Promag 50P
Electromagnetic flowmeter

Electromagnetic flowmeter - Proline Promag 50P ©Endress+Hauser

The Electromagnetic Flow Measuring Principle

The flowmeter for highest medium temperatures with a modular electronic concept

Promag P is the preferred sensor for applications with highest requirements in a multitude of industries. Combined with the proven Promag 50 transmitter with push buttons, Promag 50P offers highly accurate measurement of liquids for a wide range of applications. Promag 50P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Promag 50P is available as compact or remote version.

This product is not available in this market.

  • Benefits

    • Versatile applications – wide variety of wetted materials

    • Energy-saving flow measurement – no pressure loss due to cross-section constriction

    • Maintenance-free – no moving parts

    • Fast commissioning – application-specific Quick Setups

    • Safe operation – display...

  • Field of application

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity

    • Dedicated to chemical and process applications with corrosive liquids and high medium temperatures

    Device properties

    • Nominal diameter: max....

Features and specifications

Back

Details

  • Measuring principle

    Electromagnetic

  • Product headline

    The flowmeter for highest medium temperatures with a modular electronic concept. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

  • Sensor features

    Versatile applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals.

  • Transmitter features

    Fast commissioning – application-specific Quick Setups. Safe operation – display provides easily readable process information. Fully industry compliant – IEC/EN/NAMUR. 2-line backlit display with push buttons. Device as compact or remote version.

  • Nominal diameter range

    DN 15...600
    1/2"...24"

  • Max. measurement error

    ±0.5%
    ±0.2% (optional)

  • Measuring range

    0...9'600 m3/h

  • Max. process pressure

    PN10...40
    Cl 150...300
    JIS 10...20K
    AS 2129 Table E
    AS 4087 PN16

  • Medium temperature range

    -40...+180°C
    (-40...+356°F)

  • Ambient temperature range

    -20...+60°C
    -40...+60°C (optional)

  • Degree of protection

    IP 67 (NEMA 4x)
    IP 68 (Nema 6P)

  • Display/Operation

    Two line display with backlit
    Push button

  • Outputs

    4...20 mA
    Pulse/Frequency
    Status

  • Inputs

    Status

  • Digital communication

    HART
    PROFIBUS PA

  • Hazardous area approvals

    ATEX, IECEx, NEPSI, TIIS, FM, CSA

  • Product safety

    CE, C-tick, EAC marking

  • Pressure approvals and certificates

    PED, CRN

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • F
  • 7
  • B
    • Nr B Order code 50106079

      Kit meas. amplifier PMAG 50 ECC WEA

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039448

      Kit meas. amplifier 50 ECC WEA HE

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106081

      Kit meas. amplifier PMAG 50 ECC SEA

      Language: JA, ID, EN

    • Nr B Order code 71039450

      Kit meas. amplifier 50 ECC SEA HE

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50106080

      Kit meas. amplifier PMAG 50 ECC EES

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039449

      Kit meas. amplifier 50 ECC EES HE

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

    • Nr B Order code 50106076

      Kit meas. amplifier PMAG 50 WEA EX

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039451

      Kit meas. amplifier 50 WEA HE Ex

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106073

      Kit meas. amplifier PMAG 50 WEA

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039445

      Kit meas. amplifier 50 WEA HE

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106078

      Kit meas. amplifier PMAG 50 SEA EX

      Language: JA, ID, EN

    • Nr B Order code 71039453

      Kit meas. amplifier 50 SEA HE Ex

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50106075

      Kit meas. amplifier PMAG 50 SEA

      Language: JA, ID, EN

    • Nr B Order code 71039447

      Kit meas. amplifier 50 SEA HE

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50106077

      Kit meas. amplifier PMAG 50 EES EX

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039452

      Kit meas. amplifier 50 EES HE Ex

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

    • Nr B Order code 50106074

      Kit meas. amplifier PMAG 50 EES

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039446

      Kit meas. amplifier 50 EES HE

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

  • C
  • E
  • J
  • 21
  • G
  • 19
  • 18
  • A
    • Nr A Order code 50098018

      Kit connection board D/E/L/P/S/W FS

      Usage: 10/50/51/53/55/400/800

    • Nr A Order code 71039497

      Kit connection board D/E/L/P/S/W FS HE

      Usage: 10/50/53/55 HE = harsh environment

  • 29
  • 30
  • S
    • Nr S Order code 71003946

      Kit S-Dat Promag 50 programmed

      Serialnumber is forceful required

  • 8
  • 9
  • 10
  • 26
    • Nr 26 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 26 Order code 71247838

      Repair kit cover, remote version

      Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease

  • 15
  • 12
  • 14
  • 13
  • 20
  • 11
  • 22
    • Nr 22 Order code 50098020

      Kit parts housing compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/H/L/P/S/W

  • 24
    • Nr 24 Order code 50098019

      Kit parts housing FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W

  • 25
    • Nr 25 Order code 50098023

      Kit housing gasket FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W

  • 23
    • Nr 23 Order code 50098024

      Kit housing gasket compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/L/P/S/W

    • Order code DK5CA-

      Promag, cable remote version

      10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable

    • Order code 50XXX-

      Promag 50, transmitter

    • Order code DK5WM-

      Transmitter Promag, mounting set

      10/50/51/53/55/800

    • Order code DK5GC-

      Promag L/W/P/S,E, grounding cable kit

      A kit includes 2 cables

    • Order code DK5GD-

      Promag, grounding disc/protection disc

      Includes 1 grounding disc/protection disc

    • Order code FXA193-

      Serviceinterface FXA193

      The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.

  • Predecessor

  • Successor