Especificações resumidas
-
Process temperature
-60 °C...+280 °C
(-76 °F...+536 °F) -
Process pressure / max. overpressure limit
Vacuum...100 bar
Vacuum...1450 psi -
Min. density of medium
0.5 g/cm³
(0.4 g/cm³ optional)
Campo de aplicação
Liquiphant FTL64 has a strong focus on high temperature applications and simplicity with easy proof testing, reliability and safety (SIL) with compliance to IEC 61508, API 2350 and WHG. The vibronic device is determined for a safe and active measuring technology in applications with high temperatures and want a reliable and proven point level detection for tank overfill protection and pump dry run protection. The FTL64 is easy to use, has a digital connection and gives a real-time data at hand.
Point level switch with extension tube for pumpable liquids
Process temperature: -60 °C to +280°C (PFA coated: up to 230°C)
Process pressure: -1 to +100bar (PFA coated: up to 40bar)
Ambient temperature: -60 to +70°C
Viscosity up to 10,000mm2/s (cSt)
Optional PFA coating for aggressive media
Process connections: threads, flanges and hygienic process connection (Tri-Clamp)
International explosion protection certificates, overfill protection WHG, SIL, marine approvals
Benefícios
Universal measuring principle for limit detection – proven vibronic technology
Developed according IEC 61508 for highest safety – SIL2/3 applications (3rd party approved)
Periodic proof testing is quickly and simple organized with guided wizards via the SmartBlue-App or via a test button or magnetic pin from outside. Via digital communication you can initiate the device for a fast and easy testing of the safety loop.
Heartbeat Technology allows safe, continuous diagnostics and a simple verification, without process interruption
Centralized asset management with easy online access to all device information thanks to digital communication
Second line of defense to protect the environment
Vídeos
-
Preventive maintenance is possible with corrosion detection via Heartbeat Technology
-
Liquiphant with permanent function check is the safe choice for point level detection in liquids
Predecessor
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
| Versões FLEX | Excelência técnica | Simplicidade |
|---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
Measuring principle
Vibration Liquids
-
Characteristic / Application
Compact vibronic device for high pressure and high temperature applications,
Optional extension tube up to 6 m (19.7 ft),
Modular housing concept,
Wide range of certificates -
Specialities
Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Second line of defense,
Temperature spacer for high process temperature,
Plug and play functionalities -
Supply / Communication
19...253V AC / 2-wire,
10...55V / DC-PNP 3-wire,
9...20V DC with relay DPDT,
19...253V AC or 19...55V DC with relay DPDT,
2-wire NAMUR,
2-wire PFM,
4-20mA HART -
Ambient temperature
-60 °C...+70 °C
(-76 °F...+158 °F) -
Process temperature
-60 °C...+280 °C
(-76 °F...+536 °F) -
Process pressure / max. overpressure limit
Vacuum...100 bar
Vacuum...1450 psi -
Min. density of medium
0.5 g/cm³
(0.4 g/cm³ optional) -
Main wetted parts
316L
Alloy -
Process connection
Threads:
3/4", 1"
Flanges:
DN25...DN100
ASME 1"...4"
JIS 50A -
Sensor length
up to 6 m (19.7 ft)
-
Communication
2-wire direct load
HART
DC-PNP 3-wire
Relays
NAMUR
PFM
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI, EAC Ex, KC, JPN Ex, INMETRO, UK Ex
-
Safety approvals
Overfill protection WHG
SIL2/ SIL 3 according to IEC 61508 -
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
ASME B31.3 Process Piping
AD2000
CRN -
Marine approval
ABS/ LR/ BV/ DNV
-
Options
Ambient temperature down to -60 °C (-76 °F),
Heavy duty stainless steel housing,
Coating PFA (conductive) -
Components
FTL325P Interface PFM
FTL325N Interface NAMUR
-
-
Informações Técnicas (TI)
TI Liquiphant FTL64
-
Informações Técnicas (TI)
Versão em português - 11/2025New version available in EnglishVibronic
HART,
PROFINET por Ethernet-APLEN PT 28/11/202531/03/202503/06/202430/11/202328/02/2022Idioma:
Português
Versão:
28/11/2025
Tamanho do arquivo:
1.7 MB
Nome do arquivo:
TI01663FPT_0625-00.pdf
-
-
-
Informações Técnicas (TI)
TI Liquiphant FTL64
-
Informações Técnicas (TI)
Versão em português - 10/2025New version available in EnglishVibronic
EN PT 13/10/202502/05/202230/11/2020Idioma:
Português
Versão:
13/10/2025
Tamanho do arquivo:
1.9 MB
Nome do arquivo:
TI01540FPT_0525-00.pdf
-
-
-
Instruções de Operação (BA)
BA Liquiphant FTL64
-
Instruções de Operação (BA)
Versão em português - 10/2025New version available in EnglishVibronic
EN PT 13/10/202502/05/202230/11/2020Idioma:
Português
Versão:
13/10/2025
Tamanho do arquivo:
1.9 MB
Nome do arquivo:
BA02037FPT_0525-00.pdf
-
-
-
Instruções de Operação (BA)
BA Liquiphant FTL64
-
Instruções de Operação (BA)
Versão em português - 11/2025New version available in EnglishVibronic
PROFINET na Ethernet-APLEN PT 28/11/2025Idioma:
Português
Versão:
28/11/2025
Tamanho do arquivo:
2.1 MB
Nome do arquivo:
BA02341FPT_0225-00.pdf
-
-
-
Instruções de Operação (BA)
BA Liquiphant FTL64
-
Instruções de Operação (BA)
Versão em português - 11/2025New version available in EnglishVibronic
HARTEN PT 28/11/202531/03/202503/06/202430/11/202328/02/2022Idioma:
Português
Versão:
28/11/2025
Tamanho do arquivo:
1.8 MB
Nome do arquivo:
BA02215FPT_0525-00.pdf
-
-
-
Parâmetro do Equipamento (GP)
FTL64 HART
-
Parâmetro do Equipamento (GP)
Versão em inglês - 02/2022New version available in EnglishVibronic
EN PT 28/02/2022Idioma:
Inglês
Versão:
28/02/2022
Tamanho do arquivo:
1.1 MB
Nome do arquivo:
GP01186FEN_0121-00.pdf
-
-
-
Parâmetro do Equipamento (GP)
GP Liquiphant FTL64
-
Parâmetro do Equipamento (GP)
Versão em inglês - 11/2025New version available in EnglishVibronic
PROFINET over Ethernet-APLEN PT 28/11/2025Idioma:
Inglês
Versão:
28/11/2025
Tamanho do arquivo:
1.2 MB
Nome do arquivo:
GP01254FEN_0125-00.pdf
-
-
-
Instruções curtas (KA)
KA Liquiphant FTL64
-
Instruções curtas (KA)
Versão em português - 10/2025New version available in EnglishVibronic
EN PT 13/10/202530/09/202302/05/202230/11/2020Idioma:
Português
Versão:
13/10/2025
Tamanho do arquivo:
1 MB
Nome do arquivo:
KA01480FPT_0425-00.pdf
-
-
-
Instruções curtas (KA)
KA Liquiphant FTL64
-
Instruções curtas (KA)
Versão em português - 11/2025New version available in EnglishVibronic
PROFINET na Ethernet-APLEN PT 28/11/2025Idioma:
Português
Versão:
28/11/2025
Tamanho do arquivo:
1.6 MB
Nome do arquivo:
KA01685FPT_0225-00.pdf
-
-
-
Instruções curtas (KA)
KA Liquiphant FTL64
-
Instruções curtas (KA)
Versão em português - 11/2025New version available in EnglishVibronic
HARTEN PT 28/11/202503/06/202430/11/202328/02/2022Idioma:
Português
Versão:
28/11/2025
Tamanho do arquivo:
1.3 MB
Nome do arquivo:
KA01559FPT_0425-00.pdf
-
Escolha uma das opções sugeridas
-
-- selected coding-- selected label99.999,00<%label%>
-
Procurando mais opções? Use o configurador individual para continuar.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Procurando mais opções? Use o configurador individual para continuar.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Diagramas CAD Diagramas CAD
- Diagramas CAD
-
Preço por peça
-
<%range%><%price%>
-
- Acessórios opcionais
Configuração individual
Geralmente são fornecidos juntos
Acessórios
Produtos relacionados