- F
- L
- E
- X
Proline Promag W 10 with lap-joint flanges for basic water and wastewater applications
- F
- L
- E
- X
Proline Promag W 10 for basic water and wastewater applications
- F
- L
- E
- X
Proline Promag W 10 with remote transmitter for basic water and wastewater applications
Proline Promag W 10 with lap-joint flanges for basic water and wastewater applications
Specs at a glance
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
-
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194°F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Field of application
Thanks to its international approvals (e.g. for drinking water), Promag W serves a wide variety of applications. It is available as both compact or remote version. With its straightforward hard- and software design, Promag W 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and compliant verification.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
Suitable for elementary measurement tasks such as raw water intake.
Device properties
International drinking water approvals
Degree of protection IP68 (Type 6P enclosure)
System integration with HART, Modbus RS485
Flexible operation with app and optional display
Benefits
Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss
Flexible engineering – sensor with fixed or lap-joint process connections
Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation
Improved plant availability – sensor compliant with industry-specific requirements
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
Simple, time-saving commissioning – guided parameterization in advance and in the field
Integrated verification – Heartbeat Technology
Videos
-
Proline 10 – uncompromisingly simple
-
Accuracy on a large scale – Production and calibration of electromagnetic flowmeters up to DN 3000 (120")
-
The Electromagnetic Flow Measuring Principle
Lean selection
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter for basic water and wastewater applications with easy-to-use operation concept.
Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss.
Suitable for elementary measurement tasks such as raw water intake. -
Sensor features
Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). International drinking water approvals. Installation length: DVGW/ISO conform. -
Transmitter features
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display. -
Nominal diameter range
DN 25 to 3000(1 to 120")
-
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Volume flow, conductivity, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194°F) -
Ambient temperature range
-40 to 60°C (-40 to 140°F)
-
Sensor housing material
DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 350 to 2000 (14 to 78"): Carbon steel with protective varnish -
Transmitter housing material
Polycarbonat; AlSi10Mg, coated
-
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3 -
Display/Operation
LCD display with touch & auto rotate
-
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA -
Digital communication
HART, MODBUS RS485, IO-Link
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
CSA, GP, KC
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
CRN, PED
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Drinking water approvals: ACS, KTW-BWGL, NSF 61, WRAS BS 6920
-
-
Operating Instruction (BA)
Proline Promag W 10
-
Operating Instruction (BA)
English version - 10/2022New version available in EnglishElectromagnetic flowmeter
HARTEN 03/10/2022Language:
English
Version:
03/10/2022
File size:
4.7 MB
File name:
BA02070DEN_0222-00.pdf
-
-
-
Operating Instruction (BA)
Proline Promag W 10
-
Operating Instruction (BA)
English version - 10/2022New version available in EnglishElectromagnetic flowmeter
Modbus RS485EN 03/10/2022Language:
English
Version:
03/10/2022
File size:
4.1 MB
File name:
BA02073DEN_0222-00.pdf
-
-
-
Installation Instructions (EA)
EA Installing ground disks
-
Installation Instructions (EA)
English version - 10/2025New version available in EnglishPromag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
EN 15/10/202509/10/2020Language:
English
Version:
15/10/2025
File size:
772.1 KB
File name:
EA00070DA2_1625-00.pdf
-
-
-
Installation Instructions (EA)
EA Replacing cover, seal cover
-
Installation Instructions (EA)
English version - 03/2025New version available in EnglishProline 10
EN 15/03/2025Language:
English
Version:
15/03/2025
File size:
630.3 KB
File name:
EA01341DA2_0325-00.pdf
-
-
-
Special Documentation (SD)
SD IEC 61406
-
Special Documentation (SD)
English version - 02/2025New version available in EnglishAutomatic identification of physical objects
EN 07/02/202517/05/2024Language:
English
Version:
07/02/2025
File size:
649.2 KB
File name:
SD02825DEN_0525-00.pdf
-
-
-
Special Documentation (SD)
SD Endress+Hauser IO-Link devices
-
Special Documentation (SD)
English version - 03/2025New version available in EnglishEndress+Hauser IO-Link Add-On Instructions
for Rockwell Automation Studio 5000®EN 01/03/2025Language:
English
Version:
01/03/2025
File size:
6.7 MB
File name:
SD03386SEN_0125-00.pdf
-
-
-
Special Documentation (SD)
SD Promag
-
Special Documentation (SD)
English version - 08/2025New version available in EnglishEAC Special Documentation
EN 04/08/202502/08/2024Language:
English
Version:
04/08/2025
File size:
818.1 KB
File name:
SD03239DEN_0325-00.pdf
-
-
-
Case Study (CS)
Measuring technology for sustainable network expansion
-
Case Study (CS)
English version - 11/2025New version available in EnglishSolutions for ecological groundwater management
Language:
English
Version:
11/11/2025
File size:
1.7 MB
File name:
CS01990X11DEN1.25_Hoelscher Wasserbau_X4.pdf
-
-
-
Case Study (CS)
Messtechnik für nachhaltigen Netzausbau
-
Case Study (CS)
German version - 08/2025New version available in EnglishLösungen für ökologisches Grundwassermanagement
Language:
German
Version:
26/08/2025
File size:
858.3 KB
File name:
CS01990X11DE01.25-00_Hoelscher Wasserbau.pdf
-
-
-
Manufacturer Declaration
Product family: Promag D, Promag H, Promag P, Promag W
-
Manufacturer Declaration
English version - 10/2025New version available in EnglishProduct root: 5DBB-, 5HBB, 5PBB, 5WBB
Declaration number: HE_02162_01.25
Manufacturer specification: Performance characteristicsEN 01/10/2025Language:
English
Version:
01/10/2025
File size:
289.3 KB
File name:
HE_02162_01.25.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products