Sonda de temperatura intrinsecamente segura com iTHERM QuickNeck para rápida desmontagem da unidade eletrônica
Especificações resumidas
Accuracy
Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
fastest response time with thermowell t90 starting at below 10 s depending on configuration
Max. process pressure (static)
depending on the configuration up to 100 bar
Operating temperature range
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
Sensor de temperatura intrinsecamente seguro (conjunto RTD ou TC) com poço para termoelemento fabricado para uso com poço para termoelemento existente. Um transmissor compacto opcional com todos os protocolos de comunicação comuns – inclusivo à tecnologia Bluetooth® – e recursos especiais como iTHERM QuickNeck para fácil recalibração sem ferramentas, tecnologia do sensor e poço para termoelemento resistente a vibrações e de rápida resposta (iTHERM StrongSens, QuickSens) assim como aprovações para áreas classificadas garantem melhor precisão e confiabilidade da medição.
Faixa de aplicação universal
Faixa de medição: –200 a +1.100 °C (–328 a +2.012 °F)
Faixa de pressão de até 100 bar (1450 psi)
Grau de proteção: até IP 68
Elementos do sensor resistentes a vibrações de até 60g
Facilidade de manutenção aprimorada (substituição do sensor sem desligamento do processo), recalibração fácil e segura do ponto de medição
Benefícios
Segunda barreira do processo com indicação de falha oferecendo valiosas informações do estado de saúde
iTHERM QuickSens: tempo de resposta mais rápido do mercado 1,5 s para melhor controle do processo
iTHERM StrongSens: insuperável resistência à vibração (> 60g) para garantia de segurança do processo
iTHERM QuickNeck: economia de custo e de tempo graças à sua recalibração simples e sem ferramentas
Conectividade Bluetooth® (opcional)
Certificação internacional: proteção contra explosão conforme ATEX, IECEx, CSA C/US e NEPSI
Para enfrentar os desafios do monitoramento de temperatura em processos tão críticos, foi desenvolvido um design de poço para termoelemento que responde às mudanças no processo até cinco vezes mais rápido do que as versões padrão.
O processo Ziegler-Natta utiliza produtos químicos perigosos, como o tetracloreto de titânio. A medição precisa da temperatura é crucial para evitar reações descontroladas e garantir a segurança e a eficiência.
Torishima projeta e constrói grandes sistemas de água de resfriamento para clientes no Oriente Médio, confiando na instrumentação da Endress+Hauser pela qualidade e desempenho de seus produtos.
Explore iTHERM ModuLine industrial thermometers and thermowells. Learn more about the technical differences between the different models and discover included Endress+Hauser innovations.
O iTHERM ModuLine oferece flexibilidade total para medição de temperatura industrial. Os sensores de temperatura industriais modulares podem ser configurados individualmente para atender às necessidades do seu processo.
metric style modular temperature assembly universal range of application suitable for hazardous areas with neck or iTHERM QuickNeck incl. thermowell / protection tube (metal) or to be installed into thermowell can be used with iTHERM StrongSens, iTHERM QuickSens insert for fast response times
Thermowell / protection tube
welded protection tube or to be used with thermowell
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
Thermowell: 9x1,25 mm 11x2 mm 12x2,5 mm 14x2 mm 16x3,5 1/4" SCH80 1/2" SCH80 1/2" SCH40
straight reduced tapered optimized for quick response times
Surface roughness Ra
< 0.76 μm (0.03 μin)
Operating temperature range
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
Max. process pressure (static)
depending on the configuration up to 100 bar
Accuracy
Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
fastest response time with thermowell t90 starting at below 10 s depending on configuration
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
ATEX Ex ec, Ex tc ATEX IECEx Ex ta/tb, Ex ia, Ex db CSA C/US IS, NI, XP, DIP INMETRO Ex ia, Ex d, Ex tb NEPSI Ex ia, Ex d, Ex tD EAC Ex d, Ex ta/tb, Ex ia UKCA Ex ia, Ex nA, Ex tc KC Ex ia
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex