Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.

Chromate analyzer
Liquiline System CA80CR

Liquiline System CA80CR - Colorimetric analyzer for chromate monitoring in industrial wastewater ©Endress+Hauser
Liquiline System CA80CR - Inside view of chromate analyzer ©Endress+Hauser

Chromate concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.

Colorimetric system for the monitoring of industrial wastewater and optimization of process control

Liquiline System CA80CR offers highly accurate online measurement for optimized chromate removal in industrial wastewater. It supports you in achieving environmentally compliant electroplating and tanning processes. Like all Liquiline System analyzers, CA80CR enables plug & play of up to four Memosens sensors - minimizing the installation effort. Automatic calibration and cleaning plus advanced diagnostics with remote access ensure consistent process safety.

  • Simple products

  • Easy to select, install and operate

Technical excellence

Simplicity

  • Standard products

  • Reliable, robust and low-maintenance

Technical excellence

Simplicity

  • High-end products

  • Highly functional and convenient

Technical excellence

Simplicity

  • Specialized products

  • Designed for demanding applications

Technical excellence

Simplicity

Variable

FLEX selections Technical excellence Simplicity
  • F
  • L
  • E
  • X

Fundamental selection

Meet your basic measurement needs

Technical excellence
Simplicity
  • F
  • L
  • E
  • X

Lean selection

Handle your core processes easily

Technical excellence
Simplicity
  • F
  • L
  • E
  • X

Extended selection

Optimize your processes with innovative technologies

Technical excellence
Simplicity
  • F
  • L
  • E
  • X

Xpert selection

Master your most challenging applications

Technical excellence
Simplicity

Variable

  • Specs at a glance

    • Measurement range

      0,03 to 2.5 mg/l Cr(VI)
      0.2 to 5.0 mg/l Cr(VI)
      0.2 to 5.0 mg/l with dilution function to maximum 10 to 250 mg/l Cr(VI)

    • Process temperature

      4 to 40 °C (39 to 104 °F)

    • Process pressure

      At atmospheric pressure, < 0.2 bar absolute

please wait Loading alternative products

Quick selection

Choose from our suggested options
Sales price
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

or

Individual configuration

Continue your selection from all possible options
  • Benefits

    • Standardized colorimetric measuring principle - diphenyle carbazide method - guarantees compliance with discharge regulations.

    • Reduced operating costs through automatic calibration and cleaning and low reagent consumption.

    • Simple maintenance: no tools...

  • Field of application

    Liquiline System CA80CR supports you in improving the environmental performance of your processes by:

    • Monitoring and optimizing the cleaning capacity of industrial wastewater treatment plants.

    • Effluent monitoring in tanneries and electroplating plants.

    • ...

Features and specifications

Back

Details

  • Measuring principle

    Colorimetric

  • Characteristic

    Analyzer for Chromate (Chrome VI) in aqueous solutions

  • Size

    Housing (open version):

    793 x 530 x 417 mm

    31.22 x 20.87 x 16.42 in


    Housing (closed version):

    793 x 530 x 463 mm

    31.22 x 20.87 x 18.23 in


    Housing with base:

    1723 x 530 x 463 mm

    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)

    Outdoor version: - 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar absolute

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Suspended solids content
    Turbitity < 50 NTU, aqueous, homogenized

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors
    Automatic calibration and cleaning
    User-configurable measuring, cleaning and calibration intervals
    Optional cooling module for longer reagent shelf life
    2 channel version optional
    User-definable measuring ranges
    Modular design for easily extensible functionality
    Digital communication for remote access

  • Application

    Limit value monitoring of Chromate in potable water and waste water
    Common applications are industrial waste water Monitoring for tanneries and the galvanic industry

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Modbus RS485/TCP (optional)
    Ethernet (optional)
    Alarmrelay

  • Input

    1 or 2 measuring channels
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0,03 to 2.5 mg/l Cr(VI)

    0.2 to 5.0 mg/l Cr(VI)

    0.2 to 5.0 mg/l with dilution function to maximum 10 to 250 mg/l Cr(VI)

  • Consumables

    Reagents and standard solutions CY80CR as well as cleaner CY800 are necessary for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV800

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification