iTHERM TMS12 MultiSens Linear Multipoint

iTHERM TMS12 MultiSens Linear Multipoint ©Endress+Hauser
iTHERM TMS12 MultiSens Linear Multipoint ©Endress+Hauser

Modular straight TC and RTD multipoint thermometer with primary thermowell

The iTHERM TMS12 MultiSens Linear multipoint thermometer for oil & gas and chemical applications can be customized for various scenarios in compliance with the highest safety standards. It increases process safety by creating detailed linear temperature profiles and features a diagnostic chamber to contain and monitor leakages through the primary seals. Easy process integration reduces installation time and thus maximizes plant availability.

This product is not available in this market.

Quick selection

Choose from our suggested options
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

or

Individual configuration

Continue your selection from all possible options
  • Benefits

    • Primary thermowell for superior mechanical strength and an easy replacement of individual inserts, which are available either with TC or RTD technology

    • Increased safety thanks to a diagnostic chamber able to contain the process in the event of leakages...

  • Field of application

    • Oil & Gas industry

    • Heavy chemical processes

    • Petrochemical industry

Features and specifications

Back

Details

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style

    imperial style

    easy-to-use

    suitable for hazardous areas

    process connection: flanged

    light chemical processes

    linear sensor distribution

    modular design

    replaceable sensors during operation

    diagnostic chamber

  • Terminal head

    Junction box - aluminium - as accessory

    Junction box - stainless steel - as accessory

    Directly mounted or remote

  • Thermowell / protection tube

    with one primary thermowell (for replaceable sensors and increased mechanical protection)

  • Insert / probe

    mineral insulated (MI) sensors in a primary thermowell

  • Outer diameter protection tube / Insert

    48,3mm (1 1/2")

    60,3mm (2")

    76,1mm (2 1/2")

    88,9mm (3")

  • Max. immersion length on request

    up to 15.000,00 mm (590'')

  • Material protection tube/ thermowell

    1.4401 (316)

    1.4435 (316L)

    1.4541 (321)

    1.4845 (310L)

    1.4301 (304)

    1.4307 (304L)

  • Process connection

    flange:

    1 1/2" ASME/ANSI B16.5 150
    ...900

    2" ASME/ANSI B16.5 150
    ...900

    3" ASME/ANSI B16.5 150
    ..900

    DN40 EN/DIN 1092.1 PN10
    ...PN150

    DN50 EN/DIN 1092.1 PN10
    ...PN150

    DN80 EN/DIN 1092.1 PN10
    ...PN150

  • Tip shape

    straight

  • Operating temperature range

    Type K:

    -270 °C ...1.100 °C

    (-454 °F ...2.012 °F)

    Type J:

    -210 °C ...760 °C

    (-346 °F ...1.382 °F)

    Type N:

    -270 °C …1100 °C

    (-454 °F ...2.012 °F)

    Pt100 WW; 3mm; 316L; -200...600oC

    Pt100 TF; 3mm; 316L; -50…400oC

  • Max. process pressure (static)

    at 20 °C: 240 bar (3481 psi)

  • Accuracy

    class 1 acc. to IEC 60584

    class Special ASTM E230 and ANSI MC 96.1

    IEC60751 Class A

    IEC60751 Class AA

  • Response time

    depending on configuration:


    TC:

    t50 = 21 s

    t90 = 52 s


    RTD:

    t50 = 42 s

    t90 = 108 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX

    IECEX

    UL

    FM

    CSA

  • Certification

    SIL (transmitter only)

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
    • Order code TMT111-

      iTEMP TMT111,Transmitter DIN rail PCP

      Temperature transmitter,PC programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanical isolation. Fault reaction: NAMUR NE 43. Rail TH 35 IEC 60715. Width: 12.6 mm. Factory setup: Pt100, 3-wire, 0-100oC. Sensor type/connection optional selectable.

    • Order code TMT112-

      iTEMP TMT112,Transmitter DIN rail HART

      Temperature transmitter, HART protocol. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Rail IEC 60715. Width: 12.6mm. UL listed.

    • Order code TMT121-

      iTEMP TMT121,Transmitter DIN rail PCP

      Temperature transmitter, PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Rail IEC 60715. Width: 22.5mm. UL listed. GL (German Llyod) Marine.

    • Order code TMT122-

      iTEMP TMT122,Transmitter DIN rail HART

      Temperature transmitter, HART protocol. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Rail IEC 60715. Wide: 22.5mm. UL listed. GL (German Llyod) Marine.

    • Order code TMT125-

      iTEMP TMT125, Multichannel Transmitter

      Product being phased out, limited availability. Temperature transmitter. Application: RTD, TC, Ohm, mV. 8-channel. Galvanic isolation.

    • Order code TMT142-

      iTEMP TMT142, Field Transmitter HART

      Temperature transmitter, HART protocol. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Failure mode: NAMUR NE 43. Single compartment, NEMA 4X, IP67. UL listed.

    • Order code TMT162-

      iTEMP TMT162, Field Transmitter

      Temperature transmitter. Application: RTD, TC, Ohm, mV. HART, PROFIBUS PA Profile 3.02 or FOUNDATION Fieldbus separately available. Galvanic isolation 2 kV (sensor input/output). NEMA Type 4X Encl., IP67. Dual compartment. DNV GL marine approval (only HART). UL listed.

    • Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT187-

      iTEMP TMT187, Head Transmitter RTD

      Temperature transmitter Application: RTD. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT71-

      iTEMP TMT71, Transmitter 4-20mA

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.

    • Order code TMT72-

      iTEMP TMT72, Transmitter HART

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC

    • Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.